Sauermann Si-CA 030 Combustion Analyzer

Sauermann active

Supported models: Si-CA 030

  • Combustion Analysis
  • Ambient CO Monitoring
  • Bluetooth
  • CO
  • CO2
  • Combustion Efficiency Calculation
  • Differential Pressure
  • Draft Pressure
  • Excess Air Calculation
  • Flue Temperature
  • Gas Tightness Testing
  • Heat Exchanger Testing
  • NOx (optional)
  • O2
  • Pump Flow Rate Measurement
  • Stack Draft Measurement
  • Air Temperature
  • Temperature Differential
Connects via:
  • Direct Connect
No Beaconing

Wireless combustion analyzer with a field-replaceable O2 sensor, optional NOx capability, and a CO range up to 8,000 ppm, with measureQuick integration.

Sauermann Si-CA 030 Combustion Analyzer

The Sauermann Si-CA 030 is a wireless combustion analyzer for commissioning and servicing combustion appliances. It carries a field-replaceable O2 sensor (0 to 25%, plus or minus 0.2%) and a CO sensor reading up to 8,000 ppm, with optional NO sensor capability up to 5,000 ppm. It measures flue temperature, draft pressure, and differential pressure, computes combustion efficiency and excess air, and supports auto-zeroing, data logging, programmable CO auto-shutoff, and PDF/CSV export. A color LCD and Bluetooth connectivity stream live combustion readings into measureQuick.

Videos

Specifications

SpecificationValue
O2 sensorField replaceable, 0 to 25% (+/- 0.2%)
CO sensorFactory replaceable, 0 to 8,000 ppm (+/- 8 ppm or +/- 5%)
NOx capabilityOptional NO sensor, 0 to 5,000 ppm
Flue temperature-4 to +2282 F (-20 to +1250 C)
Draft pressure-80 to +80 inH2O (-200 to +200 mbar)
DisplayColor LCD screen
Probe180 mm standard probe
Sensor lifeO2: 5 years; CO: 4 years
Dimensions7.5 x 3.5 x 4.9 in (19.4 x 9.9 x 4.9 cm)
Weight12 oz (350 g)
ConnectivityBluetooth, mobile app