Skip to main content
Light commercial HVAC

Document every rooftop.

Light commercial means more units, more sites, and contracts that demand a paper trail. Rooftop units live or die on the air side, and most run past the static-pressure ceiling their equipment was rated for. measureQuick standardizes the diagnostic across every RTU, reads the static and airflow before the charge, and produces the documentation the maintenance agreement was sold on.

The problem

Commercial maintenance lives or dies on consistency and records.

  • Dozens of RTUs measured a dozen different ways by different techs
  • Deep filters and long duct runs that push static past the rating and choke airflow
  • Maintenance contracts that require documentation you scramble to produce
  • No baseline to show a unit is degrading before it fails
  • Multi-site accounts that expect one consistent standard

What you get

One standard across units

Quick profiles and companywide checklists mean every RTU gets the same diagnostic, no matter who is on the roof or which unit it is.

The air side first, every rooftop

Static pressure is the system's blood pressure, and most rooftop units run over the limit. A scored read checks total external static and airflow in minutes, before anyone touches the charge. Genry Garcia, owner of Comfort Dynamics, on why that matters: "now I can rest assure that my airflow measurement is measured and not assumed."

Documentation built in

Each visit produces a record that satisfies the contract and builds a performance history the customer can see at renewal.

Catch drift early

Benchmark a unit and a scored baseline turns a slow decline into a flag, so you schedule the fix on a maintenance visit instead of taking the emergency call in July.

Every site on one board

The cloud rolls every unit at every address into one dashboard, so a multi-site account gets one consistent standard and one place to see where each rooftop stands.

“Calling customers proactively because we detect a fan out of spec is a great way to over-deliver and add value. My customers appreciate that we spot small problems before they become big ones. The fastest way to lose a customer is to have their system fail, and they’re left sitting in a 95-degree house.”
Terry Zarling Owner · True Cool Air Conditioning

Questions, answered

Does the same diagnostic work on rooftop units?

Yes. Quick profiles standardize the read across every RTU, so the same scored test runs no matter who is on the roof or which unit it is.

What about static pressure on bigger commercial systems?

It is usually the first problem. Deep high-MERV filters and long duct runs push total external static past the equipment rating, which chokes airflow and drags down capacity. measureQuick reads the static and the airflow so the air side is measured, not assumed, before anyone adjusts the charge.

How does it satisfy a maintenance contract?

Each visit produces a documented record that meets the contract and builds a performance history the customer can see at renewal.

Can I catch a unit failing before it does?

A scored baseline turns a slow decline into a flag, so you schedule the repair on a maintenance visit instead of taking the emergency call in July.

Does it handle multi-site accounts?

The cloud rolls every site and unit into one dashboard, so a multi-site account gets one consistent standard and one place to see it.

Standardize your commercial maintenance.

Real-time diagnostics on 80+ tools across 17+ brands are free forever. Premier is $49 per user per month.